Abstract

This paper proposes an improved design to calculate the snubber auxiliary elements of ZVT DC-DC PWM converters with snubber assisted auxiliary switch. The proposed improved design guidelines are based on the reduction of the conduction losses through the auxiliary circuit. It is accomplished by the unique location of the turn-off snubber capacitor, which is shared by both active switches. By means of this improved design guidelines the converter efficiency can be increased. An efficiency comparative analysis is carried out and the experimental results, obtained from 1 kW, 100 kHz laboratory prototypes, show a relevant improvement in converter efficiency compared to the original converter design. In addition, experimental results also confirm that with the improved design the ZVT PWM converters with snubber assisted auxiliary switch can be competitive with ZVT PWM converters with constant auxiliary voltage source (True PWM ZVS pole).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.