The adequacy of the Bazett formula to correct for heart rate-induced changes in the QT interval of the electrocardiogram has been frequently questioned. In the present study, a simple linear equation was derived, which in anesthetized dogs corrects more adequately for changes in heart rate than the Bazett formula. Regression analysis of experimental data yielded the following equation: QT c = QT − 0.087 (RR − 1000) = QT − 87 ( 60 HR − 1) The reliability of this equation was investigated in experiments on anesthetized dogs with different cardioactive drugs with a known mechanism of action.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.