Abstract
In this paper, an improved invertor hysteresis current controller is proposed. It coordinates the switching of the three-phase switches in the d-q phase plane. In addition to the current error, information of the current error derivative is further employed so that one can take more advantage of adding the zero voltage vector for reducing the switching frequency. A simple hardware implementation of the improved hysteresis current controller is also proposed such that merits of the conventional hysteresis current controller can still be kept. Theoretical basis and some simulation and experimental results are presented to demonstrate the validity of the improved hysteresis current controller.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.