Abstract

We describe an improved, fast, automated method for screening large genes such as BRCA2 for germline genomic mutations. The method is based on heteroduplex analysis, and has been adapted for a high throughput application by combining the fluorescent technology of automated sequencers and robotic sample handling. This novel approach allows the entire BRCA2 gene to be screened with appropriate overlaps in four lanes of an ABI 377 gel. The method will detect all types of mutations, especially point mutations, more reliably and robustly than other commonly used conformational sensitive methods (e.g. CSGE). In addition we show that this approach, which relies on band shift detection, is able to detect single base substitutions that have hitherto only been detectable by direct sequencing methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.