Abstract

The experimental technique was improved with direct measurement of small torque and rotation angle to characterize micro-diameter copper wires in torsion. This method allows precise measurement of torque applied to micro-diameter wires as low as 10−8 N · m with reasonably high resolution. The rotation angle is also able to be directly measured such that the shear strain rate on the wire surface can be easily controlled. This experimental design removes the misalignment issue that has affected previous efforts in micro-diameter wire torsion testing. Using this technique, the copper wires with four different diameters (12, 16, 20, and 30 μm) were characterized in torsion. The normalized torque-rotation results showed insignificant size effects for the copper wires investigated in this study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.