Abstract
In this paper, an improved analysis of the periodic permanent magnet (PPM) focusing structure for linear beam tubes is presented. An estimation of critical dimensions for the iron pole pieces to avoid magnetic saturation is made. The method is based on the permeance calculation of all possible flux paths using magnetic circuit theory. The analytically calculated axial magnetic field using the present approach is compared with measured and simulated results obtained by using the finite-element-method-based commercial software ANSYS. The agreement is very good.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.