In this paper, we present results of measured heat transfer coefficients for each sodium carboxymethyl cellulose concentration at two different lengths of coil L=2.82m, L=2.362m and with two different heat inputs 1.0kW and 1.5kW . Test solutions of sodium carboxymethyl cellulose concentrations of 0.05%, 0.1%, 0.15% and 0.2% were used in our experimental runs. A four flat blade paddle impeller was used to verify the mixed fluid, under steady heating of Newtonian and non- Newtonian fluids in an flat bottom agitated vessel. A Kanthal Heating Element Equipment have been design and fabricated to optimize the heating of the fluids in an agitated vessel. The rehogical properties like flow behavior index, consistency index and viscosity data were carried experimentally using Rotating Cylinder Method for all the test solutions. A correlations have been presented for Newtonian and non Newtonian fluids in laminar flow conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.