Abstract

The steady-state theory of eddy-current couplings with homogeneous ferromagnetic drums is derived and shown to be valid by tests on an experimental coupling. The effect of machine parameters on peak-torque conditions and a normalized torque-speed relation are given. The flux-density distribution across the pole face under load was measured and correlated with measured torque and speed. Measurements of drum current-density and flux-density distribution through the drum thickness are also given.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.