Abstract

The plane strain fracture toughness, K Ic , and fatigue crack growth rate material properties were developed for three heats of AISI 403 modified 12 Cr stainless steel. Valid (per ASTM requirements) fracture toughness tests were conducted in the temperature range −200°F to 175°F. In addition, both the room temperature air environment plus 520°F, 1200psi distilled water environment fatigue crack growth rate material properties are presented. Finally, a hypothetical example problem is included which demonstrates the application of fracture mechanics technology to an AISI 403 modified 12 Cr stainless steel turbine rotor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.