An enzymatic flow analysis approach, based on the Griess–Ilosvay reaction, was developed for the evaluation of nitrite and nitrate, aiming at an environmentally benign alternative reduction method using nitrate reductase and the development of an in-line dilution procedure for the analysis of water samples, with a wide range of nitrate concentrations. Nitrate concentrations up to 250 mg/L can be analysed directly in the automatic system, by changing the aspirated sample volume or by applying the in-line dilution procedure provided by the automatic system. Under the optimum conditions, the calibration curves were linear up to 50 mg/L of nitrate and 3 mg/L of nitrite, with the detection limits being 0.73 mg/L and 0.03 mg/L, respectively. Nitrate and nitrite were determined in different water types by the flow method with rsd<5%. Comparison with the reference methods showed no statistically significant differences for a 95% confidence level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.