Abstract

Convective ovens require a pre-heating stage to achieve a homogenous temperature. Energy consumption is high during the pre-heating stage and proportional to pre-heating time. The pre-heating time depends on the set-point temperature. In this work a pilot scale convective oven was represented as a nominal scenario, and provided experimental data for temperature. The strategy consisted of 3-D computational fluid dynamic (CFD) simulations at different temperatures and geometrical variants of the internal baffle plate. The simulations were carried out using the ANSYS CFX package and were contrasted with experimental measurements. Results proved that the baffle plate geometry exerted an important hydrodynamic influence in the reduction of the pre-heating time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.