Abstract

Organisms of known susceptibility to antimicrobial drugs were distributed for sensitivity testing to laboratories participating in the United Kingdom National External Microbiological Quality Assessment Scheme. The results obtained were correlated with the methods used. Laboratories differed in their standards of antimicrobial drug sensitivity testing. An association between error rates and particular methods and practices enabled recommendations to be made on disc content, method of methicillin testing, preparation of inoculum, use of controls and use of lysed blood for sulphonamide testing. Some media appeared significantly better than others but because of the many factors involved further information is being sought to clarify this.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.