Abstract
A theoretical analysis is presented of the mechanism of simultaneous flow of gas and liquid through a restriction at critical speed. The study shows that a relationship exists between the mass flows of gas and liquid, restriction size and upstream pressure. Comparison of this relationship with measurements showed a reasonable agreement. It has therefore been concluded that a restriction can be used as a gas/liquid flowmeter with reasonably high accuracy, provided that the flow is a critical one. Further increase of accuracy seems possible by using a restriction especially designed for the purpose.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.