Abstract

We report ambivalent rejection behavior of a graphene oxide membrane (GOM) having a reduced interlayer spacing. Ultrathin GOMs having a thickness of 50 nm were fabricated using a vacuum filtration method followed by subjecting the samples to thermal reduction at 162 °C. The interlayer spacing of GOMs was reduced by 1 Å on thermal reduction as compared with that of the natural GOMs. The rejection rate with dye molecules was tested using dyes having three different types of charges in a dead-end filtration instrument. Rejection rate of the reduced GOM with the dyes having an opposite charge was improved up to 99.7%, indicating the dominant effect of the physical sieving diameter. In contrast, in the case of ion permeation of natural GOM, a higher rejection rate for several metal ions was observed as compared with that of GOMs having 1 Å smaller interlayer spacing, indicating the dominant effect of surface charges on the GOM samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.