Abstract

Accurate positioning of the iris is critical for the success of an ocular prosthesis. Precise duplication of size and location of the iris is essential for the establishment of realism, symmetry, and a natural-appearing gaze. This article explores an alternative procedure for positioning the iris in a custom-made ocular prosthesis using a pupillary distance ruler (PD ruler). The orientation and mediolateral dimension of the iris of the natural eye was measured from the graduated scale on a PD ruler and transferred on to the sculpted scleral wax pattern. The iris button was positioned in the marked area, and the established orientation was evaluated for symmetry and a natural-appearing gaze. Accurate, predictable, and easy positioning of the iris with the transfer of these dimensions to the definitive prosthesis provided a good result in terms of patient esthetics and satisfaction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.