Abstract

Many alternatives are being investigated for the carbon capture, but none appears to have been proved as the choice for full-scale applications. This work considers the Chilled Ammonia Process for coal-fired Ultra Super Critical power plants. Three layouts are simulated with Aspen Plus and the Extended UNIQUAC thermodynamic model. Compared to a traditional layout, stripping of the wash water of the absorber or, better, splitting the rich solution between the middle and the top of the column limits greatly the ammonia slip. Moreover, splitting the regeneration over two levels reduces substantially the electric loss due to stream extraction from the turbine. The simulations show that the net electric efficiency drops from 45.5% to 33.5-34.5%, the SPECCA index is 3.8-4.3 MJth kgCO2–1 and the heat duties are 2.7-2.9 MJth kgCO2–1. The performances may improve greatly upon optimization of the parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.