Abstract
In this work, the alkaline refining of arsenic in crude lead was studied with a mixture of sodium hydroxide and sodium carbonate as alkaline refining agents. Taking the arsenic removal rate as the research object, the effects of reaction temperature, holding time, Na2CO3:NaOH, the dosage of refining agent were investigated. The arsenic removal rate is 79.09% under the optimum experimental conditions as follows: reaction temperature 823 K, holding time 60 min, Na2CO3:NaOH 1:4, refining agent dosage 10%. The oxidation purification mechanism of arsenic was studied by XPS, SEM-EDS, XRD and FT-IR. The results show that arsenic in the crude lead is gradually oxidized by oxygen and lead oxide during arsenic removal process, and the arsenic trioxide is eventually converted into sodium arsenate (Na3AsO4) and lead arsenate (Pb2As2O7) in the slag.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.