Abstract

In this paper a mathematical formulation for the air leakage rate through cracks in concrete is given. The formula works well as a good approximation for crack widths up to 1.30 mm and overpressures up to 0.80 MPa. The formula was found by means of systematic air leakage tests using unreinforced test specimens with one “defined single crack”. For thermodynamic formulation, isothermal changes in the gas state during the leakage through the crack was estimated and experimentally proved. By additional leakage tests using reinforced test specimens, practical usability of the leakage formula for reinforced panels with a “typical crack pattern” was checked.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.