Abstract

Air infiltration rates were measured via a tracer dilution method in 10 eastern Washington houses before and after the houses were weatherized in order to determine the effectiveness of weatherization procedures. Infiltration rates during typical meteorological conditions ranged from 0.3 to 1.0 air exchanges per hour (ex/h) among the houses. Reduction in these infiltration rates due to weatherization also varied considerably from essentially no change to 40% reduction in the air exchange rate. The average reduction in the air infiltration rate was approximately 16%. Infiltration rates were measured continuously in one house during several weeks and the results showed that the extended use of doors can cause infiltration rates to increase from less than 1 ex/h for a closed house to more than 3 ex/h. Limited air pollution measurements conducted during the study indicated that formaldehyde and radon concentrations were quite low indoors while individual hydrocarbon concentrations indoors were much higher tha...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.