Abstract

This paper describes the results of a laboratory study of air entrainment below drops for a range of Drop numbers from 0.0007 to 0.0046. Characteristics of the plunging flow that occurs when the tailwaler depth yt is in the range of yt* . to h were studied where yt* . is the value of yt when a hydraulic jump is formed at the section where Ihe deflected stream below the drop becomes parallel to the bed and h is the height of the drop. Air entrainment below the drop was studied for the jump with yt = yt* as well as for the plunging flows and approximate expressions have been developed for their air entrainment rates. These results can contribute to the estimation of the reaeration of polluted streams below drops.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.