ABSTRACT This article presents an application of Material Flow Analysis (MFA) and Quantitative Microbial Risk Assessment (QMRA) as means for advanced sanitation planning in order to quantify domestic waste flows and to estimate microbial infectious risks. The main domestic waste flows include sewerage, greywater from households, effluent of on-site sanitation systems, and illegal dumping of fecal sludge. These flows could cause the contamination of E. coli in canals at the concentration range of 9.0E+01 to 9.2E+04 MPN/100 ml. This study analyzed three scenarios of domestic waste managements: (1) household greywater treatment, (2) fecal sludge treatment, and (3) sewerage treatment, resulting in substantial reduction of E. coli concentrations in those treated effluents. Subsequently, QMRA results could confirm whether the yearly infectious risks due to the uses of treated effluents were lower than the acceptable risk of 1.0E-04 (USEPA 1994). With the aforementioned conditions, this research could demonstrate the potential as an advanced sanitation planning tool by integrating MFA and QMRA methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.