Abstract

Abstract Fault localization on functional macros during advanced technology development requires a complex combination of tester based diagnostics and image based techniques including laser voltage imaging (LVI), laser voltage probing (LVP), critical parameter analysis (CPA) with laser stimulation and photon emission microscopy (PEM). These techniques are exemplified in the following three case studies. The first case involves a voltage sensitive SRAM block fail which was localized to a resistive via through the use of CPA, LVI and LVP. The second case demonstrates how a hard fail (a net-to-net metal short) in a scan chain was localized through use of tester based diagnostics, LVI, LVP and PEM. Finally, the last case shows how a condition sensitive failing latch chain was localized through CPA, LVI, LVP and PEM. Subsequent atomic force probing (AFP) identified source-drain leakage in one of the localized devices, and TEM analysis revealed a dislocation in the failing FET. Each of these cases demonstrates the value in utilizing tester based diagnostics along with laser based imaging and photon emission microscopy to localize failures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.