Abstract

ABSTRACTSilicon wafers coated with a 5μm thick layer of polyimide were treated with different surface modification techniques such as chemical adhesion promoters, oxygen plasma and an Ar+ sputter etch. After surface modification, the wafers were molded with a 1mm thick layer of PDMS. The adhesion of the PDMS was tested by peel testing and by using a Nordson DAGE wedge shear tester. It was found that commercially available chemical adhesion promoters and oxygen plasma treatment resulted in a very poor PI/PDMS adhesion, whereas the Ar+ sputter etch resulted in an adhesion so strong that the PDMS could not be delaminated from the PI surface without the failure of the material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.