Abstract
A major disadvantage of applying sliding mode control to dc/dc converters is that the steady-state switching frequency is affected by line and load variations. This is undesirable as it complicates the design of the input and output filters. To reduce switching frequency deviation in the events of line and load variations, an adaptive feedforward control scheme that varies the hysteresis band according to the change of line input voltage and an adaptive feedback control scheme that varies the control parameter (i.e., sliding coefficient) according to the change of the output load are proposed. This paper presents a thorough investigation into the problem and the effectiveness of the proposed solutions. In addition, methods of implementing the proposed adaptive control strategies are discussed. Experimental results confirm that the adaptive control schemes are capable of reducing the switching frequency variations caused by both line and load variations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.