Abstract

to determine the accuracy of fine-needle aspiration biopsy (FNAB) and of core-needle biopsy (CNB) in diagnosing breast lumps and breast cancer. this was a cross-sectional, retrospective and descriptive study based on the review of medical records. FNAB and CNB were carried out sequentially according to the routine of the Mastology Service. Both percutaneous procedures were applied to 233 patients during the period from March 2005 to February 2007. Women aged 18 years or more with changes in the clinical and/or image examination of the breast or a family history of breast and/or ovarian cancer were included. FNAB and CNB were carried out according to the technical recommendations of the National Institute of Cancer. The percentage of agreement, Cohen's Kappa coefficient, sensitivity, specificity, positive and negative predictive values and the accuracy of FNAB and CNB were calculated, considering the surgical biopsy as the gold standard. the average age of the patients was 49.0 years (±12.7) and the tumors measured 26.9 mm on average (±23.1), being larger than 20 mm in 47.2% of cases. Sensitivity, specificity, positive and negative predictive values and accuracy were higher for CNB than for FNAB, regardless of the size of the breast lesion. The diagnostic accuracy was 97.5% for CNB and 77.5% for FNAB. although the CNB showed higher rates of sensitivity, specificity, positive predictive value, negative predictive value and accuracy than FNAB for palpable and non-palpable breast lumps, the method remains useful for the minimally invasive diagnosis of mammary lesions, especially when its results are analyzed together with the clinical and imaging examination.

Highlights

  • PURPOSE: to determine the accuracy of fine-needle aspiration biopsy (FNAB) and of core-needle biopsy (CNB) in diagnosing breast lumps and breast cancer

  • Trata-se de um estudo retrospectivo, transversal e descritivo, em que foram analisados os resultados de por agulha fina (PAAF) e por agulha grossa (PAG) guiada por ultrassonografia, como rotina, em pacientes do Serviço de Mastologia do Instituto Fernandes Figueira da Fundação Oswaldo Cruz (FIOCRUZ), entre março de 2005 e fevereiro de 2007

  • Conforme demonstrado na Tabela 2, a PAG apresentou maiores taxas de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia quando as amostras insatisfatórias foram classificadas como malignas

Read more

Summary

Introduction

PURPOSE: to determine the accuracy of fine-needle aspiration biopsy (FNAB) and of core-needle biopsy (CNB) in diagnosing breast lumps and breast cancer. Trata-se de um estudo retrospectivo, transversal e descritivo, em que foram analisados os resultados de PAAF e PAG guiada por ultrassonografia, como rotina, em pacientes do Serviço de Mastologia do Instituto Fernandes Figueira da Fundação Oswaldo Cruz (FIOCRUZ), entre março de 2005 e fevereiro de 2007.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.