Abstract

In this paper, condition monitoring of the internal parts of a radial active magnetic bearing (AMB) system is performed by means of Cepstrum analysis, Wigner-Ville Distributions (WVD) and enveloped Equi-Sampled Discrete Fourier transforms (ESDFT). Sensor faults, power amplifier failures and controller faults were induced in both the simulation and physical AMB system. Condition monitoring by means of the abovementioned techniques were then performed on the displacement and current signals of the simulation and physical AMB system. Results were compared and conclusions were made on how effective Cepstrum analysis, WVD and enveloped ESDFT were on the faults induced on the AMB system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.