Abstract

The performances for controlling a rotating machine by using either an Electromagnetic Actuator or a Piezoelectric Actuator are compared in this work. The aim is to establish selection criteria based on environmental impact. Life Cycle Analysis shows that the operating stage has a considerable impact. In this study, only the operating stage is considered. The energy consumed by the actuators seems to be the appropriate indicator for the same mechanical performances. Numerical studies are carried out in order to quantify the energy consumed in each case. Modal control strategy with a fuzzy controller is used. The controller inputs are displacements and velocities. The system studied is modeled by using finite element method and the electrical circuit of each actuator is modeled by using basic electricity and electromagnetism theories. Several configurations are assessed and defined by using the chosen Functional Unit.The results obtained show that both controllers are efficient and enable recommendations for optimal control procedures design for the energy consumed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.