Abstract

In an experimental evaluation with 14 paired cadaveric scapulae we found that the transacromial arthroscopy portal, used occasionally in the repair of superior labral lesions, will reduce the structural integrity of the acromion to approximately 60% (range 25% to 85%) of its original strength, thereby placing it at increased risk of fracture. These studies provide baseline biomechanical information and suggest that limited shoulder activity is indicated after use of this portal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.