Abstract

The aim of this study was to assess acoustically selected sacred buildings located in Szczecin. The research part contains the research methodology and the results obtained. The research was carried out using two methods. The first one is the integrated impulse response method, where, using a bursting balloon, the time of sound pressure drop was measured at selected points of the object. In the interrupted noise method, the sound pressure drop was measured after the noise generated by the omnidirectional loudspeaker had ceased. Reverberation time was calculated for the results obtained, which is the main and basic parameter determining the interior acoustics. On the basis of the above-mentioned measurements, the reverberation indicators for the temples were also calculated. When analyzing the components of the reverberation indicator, it was noticed that poor acoustics in the sanctuary concerns speech, while interior acoustics is good for the reception of organ music. In the analyzed church, the reception of liturgical music is also better than the reception of speech, but the differences between these values are small.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.