The critical-points method for direct characterization of high-Q microwave resonators is adapted to low-Q resonators. Based on a new approximation, the crossover points are removed and the critical points are used in the computation of the equivalent-circuit elements for the low-Q resonator. Due to the large separation of the crossover frequencies from the resonant frequency, the modification is necessary in order to have a good estimate of the element values in the equivalent circuit. The high accuracy of this one-port measurement method is verified using a microstrip patch antenna.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.