Abstract

Objective To evaluate the accuracy of systolic pressure variation (SPV) in monitoring blood volume in patients.Methods Twenty-two ASA Ⅱ or Ⅲ patients (17 male,5 female),aged 49-79 yr,with body height 153-173 cm,weighing 55-89 kg,scheduled for elective coronary artery bypass grafting under cardiopulmonary bypass,were studied.Stroke volume variation (SVV) was monitored based on the arterial pressure wave and SPV measured based on the invasive arterial pressure wave after changing the title.After the chest was closed,the volume load test was immediately carried out.6% hydroxyethyl starch 130/0.4 50-80 ml/min was infused via the jugular vein until cardiac index (CI) increased by 10%.HR,mean arterial pressure (MAP),SPV,CI,SVV,stroke volume index (SVI),systemic vascular resistance index (SVRI),central venous pressure (CVP),and pulmonary capillary wedge pressure (PCWP) were recorded in supine position (T1),at 30° head-down tilt before skin incision (T1'),before (T2) and after opening the chest in supine position (T2'),before (T3) and after the volume load test in supine position after closing the chest (T3'),in supine position after skin closure (T4),and at 30° head-down tilt after skin closure (T4').The difference in SPV and SVV (△SPV and △SVV) was calculated.The receiver operator characteristic curve for △SVV and △ SPV in determining blood volume changes was plotted.Results MAP,CVP,PCWP,CI,and SVRI were significantly increased,while SVV and SPV were decreased at T1' compared with those at T1 (P < 0.05).HR was significantly increased,while CVP was decreased at T2' compared with those at T2 (P < 0.05).MAP,CVP,PCWP,and CI were significantly increased,while SVV and SPV were decreased at T3' compared with those at T3 (P < 0.05).MAP,CVP,and PCWP were significantly increased,while SVV and SPV were decreased at T4' compared with those at T4 (P < 0.05).The area under receive operator characteristic curve for △SVV and △SPV in determining blood volume changes was 0.603 and 0.616 respectively,and there was no significant difference (P > 0.05).Conclusion SPV can accurately monitor the blood volume in patients. Key words: Blood pressure; Vascular capacitance; Monitoring,intraoperative

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.