Abstract

ABSTRACTOne of the most important steps is accurate impression making for fabrication of fixed partial denture.The two different putty-wash techniques that are commonly used are: (1) Putty-wash one-step technique, (2) putty-wash two-step technique.A uniform wash space is needed for an accurate impression. Nissan et al recommended the use of two-step technique for accurate impression making as there is uniform wash space for the light body material to polymerize.The aim of the present study was to compare the accuracy of stone casts obtained from different putty-wash impression techniques using various spacer thickness.The critical factor that influences the accuracy of putty-wash impression techniques is the controlled wash bulk which is absent in one-step putty-wash impression technique and with polyethylene spacer was used.How to cite this article: Chugh A, Arora A, Singh VP. Accuracy of Different Putty-Wash Impression Techniques with Various Spacer Thickness. Int J Clin Pediatr Dent 2012;5(1):33-38.

Highlights

  • One of the most important steps is accurate impression making for fabrication of fixed partial denture

  • Nissan et al recommended the use of two-step technique for accurate impression making as there is uniform wash space for the light body material to polymerize

  • Clinical success of fixed prosthodontic procedure is dependent upon the dimensional accuracy of elastomeric impression material and impression procedures

Read more

Summary

INTRODUCTION

One of the most important steps is accurate impression making for fabrication of fixed partial denture. The two different putty-wash techniques that are commonly used are: (1) putty-wash one-step technique, (2) putty-wash twostep technique. A uniform wash space is needed for an accurate impression. Nissan et al recommended the use of two-step technique for accurate impression making as there is uniform wash space for the light body material to polymerize. Putty acts as a tray for wash material. Light body being less viscous has good flow to record the fine details resulting in an accurate impression. An accurate impression produces the stone casts with minimal dimensional change in regard to the vertical and horizontal dimension between the prepared abutments. Clinical success of fixed prosthodontic procedure is dependent upon the dimensional accuracy of elastomeric impression material and impression procedures

AIMS AND OBJECTIVES
MATERIALS AND METHODS
Measuring Procedure
DISCUSSION
SUMMARY AND CONCLUSION
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.