Abstract
Expressions are provided for the accuracy of monopulse angle estimation using two beams. It is shown that, if the signal angle is halfway between the angles of the beams, the Cramer-Rao lower bound (CRLB) for monopulse processing is almost as small as the CRLB obtained if the entire array of sensors is used. The monopulse CRLB is considerably poorer if the angle of the signal is equal to that of one of the two beams. The expressions in this correspondence are for a uniformly weighted linear array of M equally spaced sensors, for which N/spl ges/M beams are formed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Aerospace and Electronic Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.