Abstract

Summary form only given. Insertion loss is derived in terms of generator impedance, load impedance and filter open-circuit and short-circuit impedances. This expression contains a difference term which places great weight on the accuracy with which filter's impedance are measured. It is shown that the use of this difference term can be avoided by introducing the filter's insertion loss in a circuit with known generator and load impedances. The resulting exact expression contains terms which are easily measurable with sufficient accuracy to provide reliable insertion loss values for the filter for any combination of generator and load impedances. Also shown is a simplified approximate expression for insertion loss which is applicable to a filter's attenuation band. A discussion of experimental verification of the expressions is followed by curves showing application of the approximate insertion loss expression to a particular filter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.