Introduction: Patients with end stage renal disease (ESRD) often progress to hemodialysis (HD), where permanent access such as arteriovenous fistula (AVF) is needed. Due to associated cardiovascular comorbidities, several of these patients also require cardiac implantable electronic devices (CIEDs) for pacing or defibrillation needs. HD vascular access is their lifeline, yet prolonged use is fraught with complications which often necessitate the eventual use of both upper extremities. Conventional CIEDs require placement of leads through subclavian veins which limits the ability to use that extremity for AVF. Novel devices such as subcutaneous defibrillator and leadless pacemakers do not require placement of leads in the upper extremity and may offer an advantage in HD patients to preserve both upper extremities for AVF. Objective: To compare the incidence of successful use of contralateral upper extremity for AVF following HD access failure in patients with novel and conventional devices. Methods: This study included all patients who underwent placement of novel leadless and conventional devices during the last 10 years at the Ohio State University. Incidence of successful use of contralateral upper extremity for AVF following HD access failure was assessed as the primary outcome. Incidence of initial HD access failure was assessed as a secondary outcome. Results: A total of 58 patients with novel devices (subcutaneous defibrillator: 30 and leadless pacemaker: 28) comprised the interventional group, while a total of 25 patients with conventional devices comprised the control group. The primary outcome occurred in 18% of the interventional group and 0% of the control group (p < 0.01). Incidence of initial access failure was 46% in the interventional group and 40% in the control group (p= 0.2). Conclusion: Patients on HD have a high incidence of access failure and often require use of the contralateral upper extremity for AVF. Presence of novel devices provides the option for contralateral access compared to conventional transvenous devices. Where possible and clinically indicated, novel devices should be preferred over conventional transvenous devices in ESRD and HD patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.