Abstract

Radiation doses to the skin, bone marrow, and gonads were determined during endoscopic retrograde cholangiopancreatographic examinations. Average patient entrance doses were 7.5, 4.9, 17.5 and 2.7 rads to the abdomen, back, and left lateral and right lateral positions, respectively. Mean active bone marrow dose was 0.4 rads and average gonadal dose was 0.2 rads. Spot radiographs and fluoroscopy provided equal contributions to patient dose. Patient entrance dose was less than that from abdominal angiography, and comparable to that from a typical upper-gastrointestinal series. The pancreatic dose was comparable to that from a radionuclide scan. Dose to personnel was negligible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.