Abstract

Ablation layers are deposited on DT-filled glass microballoon targets by a parylene coating scheme while the targets are bounced on the surface of a mechanical resonator. Optimum bouncing is achieved with the resonator surface moving with a peak vertical velocity of ∼3 cm/s at a frequency much greater than the bounce frequency of the targets. The resonator, a solid cylinder of high-Q material, uses a longitudinal mode of vibration to achieve vertical motion, which is uniform over its surface. A flexural mode of the cylinder is used for dislodging targets which have become stuck. In their natural state, the targets become charged triboelectrically and by the beta emission from the tritium decay. The adhesion of these charged targets is eliminated by creating a low power plasma in the bouncing region. Real time monitoring and control of coating thickness are achieved by use of a laser reflectometer. Coatings are examined with electron microscopy and x-ray radiography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.