Abstract

This paper presents a new structure of the subsampling phase detector (SSPD) and charge pump in Subsampling phase locked loop (PLL). In contrast with traditional Subsampling phase locked loop (SSPLL), it has no frequency- locked loop (FLL), but has a larger frequency acquisition range. It combines SSPD with a conventional phase frequency detector/charge pump (PFD/CP) to ensure a wide operating range. A range detector is designed to distinguish the big and small phase error. When the phase error is small, the charge pump is controlled by the sampling voltage (Vsam), otherwise controlled by the output of the phase detector (PD) and charge pump (CP).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.