Abstract
A new wide area differential protection (WADP) system is proposed to suit the need of the shipboard application where short cables make conventional backup schemes impractical. The close proximity of all the components in a shipboard power system makes communication less of an issue than in a land-based system. With an overall view of the protected system and by use of a differential search algorithm, a minimum fault isolation area is decided. A built-in confirmation mechanism avoids unnecessary or false tripping due to protection component failure. The principle of the WADP system is described in detail in this paper. Simulation results are shown for a small Shipboard Power System (SPS).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.