Abstract

A simple, isocratic, rapid and accurate reversed phase high performance liquid chromatography method was developed for the quantitative determination of tazarotene. The developed method is also applicable for the related substance determination in bulk drugs. The chromatographic separation was achieved on a Hypersil C18 (250 mm × 4.6 mm 5 μm) column using water pH 2.5 with orthophosphoric acid:acetonitrile (15:85, v/v) as a mobile phase. The chromatographic resolutions between tazarotene and its potential impurity A and B were found greater than three. The limit of detection and limit of quantification of impurities were found to be 25 and 75 ng mL−1. The percentage recovery of impurities in bulk drug sample was ranged from 96.8 to 103.5.The percentage recovery of tazarotene in bulk drug sample was ranged from 98.4 to 100.9. The developed RPLC method was validated with respect to linearity, accuracy, precision and robustness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.