Abstract

This paper proposes the application of the asymmetrical duty cycle to the three-phase dc/dc pulse-width modulation isolated converter. Thus, soft commutation is achieved for a wide load range using the leakage inductance of the transformer and the intrinsic capacitance of the switches, as no additional semiconductor devices are needed. The resulting topology is characterized by an increase in the input current and output current frequency, by a factor of three compared to the full-bridge converter, which reduces the filters size. In addition, the rms current through the power components is lower, implying the improved thermal distribution of the losses. Besides, the three-phase transformer allows the reduction of the core size. In this paper, a mathematical analysis, the main waveforms, a design procedure, as well as simulation and experimental results obtained in a prototype of 6 kW are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.