Abstract

A special three-dimensional crack-tip element has been developed to investigate a simple and widely applicable fracture toughness test method. Previous experimental work with the double-torsion method has shown that the use of a relatively thin sectioned specimen may be permitted. The section concerned is considerably thinner than that used in conventional techniques, while the technique also simplifies the determination of the fracture toughness parameter. K IC values, which are independent of the crack length, have been obtained for glasses, ceramics, polymers, and a variety of metals and alloys. The numerical solution presented is supportive of many experimental observations made during testing. Excellent correlation between the finite element and experimental results has been obtained. The maximum stress intensity factor is shown to be almost independent of crack length over a considerable range.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.