Abstract

An interactive source-filter system, consisting of a three-mass body-cover model of the vocal folds and a wave reflection model of the vocal tract, was used to test the dependence of vocal fold vibration on the vocal tract. The degree of interaction is governed by the epilarynx tube, which raises the vocal tract impedance to match the impedance of the glottis. The key component of the impedance is inertive reactance. Whenever there is inertive reactance, the vocal tract assists the vocal folds in vibration. The amplitude of vibration and the glottal flow can more than double, and the oral radiated power can increase up to 10 dB. As F 0 approaches F 1, the first formant frequency, the interactive source-filter system loses its advantage (because inertive reactance changes to compliant reactance) and the noninteractive system produces greater vocal output. Thus, from a voice training and control standpoint, there may be reasons to operate the system in either interactive and noninteractive modes. The harmonics 2F 0 and 3F 0 can also benefit from being positioned slightly below F 1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.