Abstract

The presented technique describes the steps for fabricating a hollow and rigid intranasal stent to maintain the patency of the nasal passage after iatrogenic nasal vestibular stenosis in an infant. The technique uses a connector between the injection bulb or site and the hypodermic needle of an intravenous infusion set to ease the impressionmakingand avoid the additional step of hollowing the stent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.