Abstract

Computed tomography scans are a valuable tool for developing computational models of bones. The objective of this study is to present a method to generate CAD representations of long bones from clinically based CT scans. A secondary aim is to apply the method to six long bones from a sample of three individuals. Periosteal and endosteal bone surfaces were segmented and used to calculate the characteristic cortical thickness, Tc, at 1 mm increments along the bone axis. In the epiphyses where the value of Tc fell below the scanner threshold, the endosteal bone layer was replaced using literature values projected inward from the periosteal surface. On average, 74.7 ± 7.4% of the bone geometry was above the scanner cut-off and was therefore derived from the CT scan data. The thickness measurement was also compared to experimental measurements of cadaveric bone and was found to predict Tc with an error of 3.1%. This method presents a possible solution for the characterization of characteristic thickness along the length of the bone and may also aid in the development of orthopedic implant design and subject specific finite element models.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.