Abstract

A new variant of the four-electrode system is proposed for geophysical resistivity investigations, particularly for profiling over conductive bodies. Model tank resistivity profiling experiments with Wenner, Schlumberger and the proposed T-shaped four-electrode arrays were carried out over a thin conducting vein type model to evaluate the efficacy of the new array. The proposed array appears to possess a larger response, a greater depth of investigation and a higher vertical resolution in detecting conducting bodies, as compared to the two-conventional arrays.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.