Abstract

A dual probe non-contact ball roundness measurement method is presented in this paper. With two probes aligned in opposite directions, the direct measurement of diameter variation can be obtained. The relationships between diameter variation and out of roundness of a precision ball are discussed. Attempts of error separation using multiple measurements are carried out and the eccentricity of ball and spindle axis is measured. Measurement results indicated that other than the spindle radial run out, which is synchronous in nature, there also exists high frequency non-synchronous variations. Such non-synchronous errors can be effectively eliminated with the dual probe arrangement for diameter variation measurement. The measurement results showed that such set up is capable of measuring high precision balls for diameter variation and out of roundness with uncertainty of less than 10nm. Single measurement can be completed in 10 seconds with over 10,000 data points. Faster measurement is possible with improved air bearing spindle. The method is suitable for online application of precision ball diameter variation and out of roundness measurement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.