Abstract
A very quick response air mass flowmeter for accurate measurement of intake air of internal combustion engines was developed. This flowmeter consists of a disk-type anode surrounded by two coaxial cylinders which serve as the first and second cathodes. Steady state flow tests show this flowmeter has sufficient accuracy, linearity, and directivity and no hysteresis is observed. The effects of temperature, pressure and humidity of the air are studied. For pulsating air flow, this flowmeter showed excellent dynamic response. Furthermore, this meter succeeded in measuring the intake air flow rate of a single cylinder spark ignition engine under firing conditions. Therefore, this flowmeter is very useful not only for analyzing transient characteristics of internal combustion engines but also for the accurate control of the fuel injection systems of gasoline engines.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.