Abstract

The effect of variables associated with the donor and with methods of collecting, processing, and storing platelets on the quality of platelets kept at ambient temperature was studied. Changes in structural integrity of platelets, decrease in pH, loss of aggregability, and kinetics in vivo of platelets tagged with 51Cr were used as indicators of the tolerance of platelets to storage. A platelet concentration of less than 2.5 x 10(6) per cu mm, a temperature of storage less than 24 C, and continuous, gentle, agitation were found to be essential for satisfactory preservation of platelet integrity, function, and post-transfusion survival. Platelets from female donors tolerated storage less well than did platelets from male donors, possibly because the lower hematocrit of blood collection from females resulted in greater initial acidity of the concentrate. A number of other variables analyzed appear to be of little or no consequence for successful platelet storage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.