Abstract

A synchrotron radiation absorption experiment was used to measure the absolute density of ground level Hg atoms and Hg+ ions in Hg–Ar discharge plasmas at high power densities. Ion densities from this experiment were tested using microwave interferometry and compared with Langmuir probe measurements of the electron density. Radial cataphoresis was observed in this experiment and compared with model predictions. The agreement was satisfactory between the experiment and model. The role of cataphoresis in the power balance of Hg–Ar plasmas was further explored in the research described in the companion paper (Lister et al. 2004 J. Phys. D: Appl. Phys. 37: 3099–3106).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.